The IS Series - Mid-Frequency Inverter Weld Controls feature closed-loop current, voltage, and power feedback, fast response times, and a wide range of output power - 0.050-80 kA in 4 ranges. This makes them ideal for small or large, single or mixed part manufacturing.
Six different weld control models allow the user to select the best mode for the application: primary limit, primary and secondary RMS, power RMS, voltage conrole or pulse percent.
Packaged in a NEMA enclosure, the new units come as standard with a rotary handle and internal circuit breaker. It has a “triple pulse” weld capability which provides flexible weld profiles and enables three pulses in each cycle. Each weld segment can be programmed with upslope and downslope and may contain up to 19 pulses.
. | IS800 AMY-Global Version | IS-1400 AMY-Global Version |
---|---|---|
Maximum primary output current (peak) | 1400 amps @ 3% | 4000 amps @ 12% |
Settings - Constant current | 0.05 - 80.0 kA | 1.00-260 kA |
Settings - Constant power | 0.05-120 kW | 0.50-390 kW |
Settings - Constant voltage | 0.20-9.99 V | 0.20-9.99 V |
Settings - Fixed pulse | 10.0-99.9% | 10.0-99.9% |
Weld monitors - Current | 0.0-99.9 kA | 0.0-300.0 kA |
Weld monitors - Power | 000.0-999.9 kW | 000.0-999.9 kW |
Weld monitors - Voltage | 0.00-9.99 V | 0.00-9.99 V |
Weld monitors - Pulse % | 10.0 - 100.0% | 10.0 - 100.0% |
Power source | 380 - 480 VAC, Three Phase, 50/60 Hz, +- 10% | 380 - 480 VAC, Three Phase, 50/60 Hz, +- 10% |
Output frequency | 600 - 1000 HZ | 600 - 100 HZ |
Control modes | Primary constant current control, Primary limit control, Secondary RMS control, Power RMS control, Voltage control, Pulse % control | Primary constant current control, Primary limit control, Secondary RMS control, Power RMS control, Voltage control, Pulse % control |
Number of schedules | 255 (Selectable by pendant or external I/0) | 255 (Selectable by pendant or external I/0) |
Time settings: Squeeze delay | 0000-9999 (ms) / 0000-9999 (CYC) | 0000-9999 (ms) / 0000-9999 (CYC) |
Time settings: Squeeze | 0000-9999 (ms) / 0000-9999 (CYC) | 0000-9999 (ms) / 0000-9999 (CYC) |
Time settings: Upslope | 000-999 (ms) / 00-50 (CYC) | 000-999 (ms) / 00-50 (CYC) |
Time settings: Weld | 000-999 (ms) / 00-50 (CYC) | 000-999 (ms) / 00-50 (CYC) |
Time settings: Cool | 0000-9999 (ms) / 0000-9999 (CYC) | 0000-9999 (ms) / 0000-9999 (CYC) |
Time settings: Down slope | 000-999 (ms) / 00-50 (CYC) | 000-999 (ms) / 00-50 (CYC) |
Time settings: Hold | 00000-20000 (ms) / 00000-00999 (CYC) | 00000-20000 (ms) / 00000-00999 (CYC) |
Time settings: Off time | 0 or 0010 - 9990 (ms) / 0000 - 0099 (CYC) | 00000-20000 (ms) / 00000-00999 (CYC) |
Time settings: Pulsation setting | 01-19 (settable for WELD 1 to WELD 3, respectively | 01-19 (settable for WELD 1 to WELD 3, respectively |
Transformer turns ration | 1.0-199.9 | 01-19 (settable for WELD 1 to WELD 3, respectively |
Valve setting | Up to 6 valves - including proportional valve | Up to 6 valves - including proportional valve |
Control gain (GAIN) | 1-9 | 1-9 |
Step-up/-down (STEPPER COUNT) | STEP 1-9 (9 steps), UP (down) ratio (RATIO) 50-200%, Counter setting (COUNT) 0000-9999 | STEP 1-9 (9 steps), UP (down) ratio (RATIO) 50-200%, Counter setting (COUNT) 0000-9999 |
Weld count monitor (PRESENT COUNT) | 0000-9999 | 0000-9999 |
External communication | RS-232 (single or bi-directional) | RS-232 (single or bi-directional) |
Program protect | Programming protected when active | Programming protected when active |
EU Certification | CE compliant | CE compliant |
WEIGHT & DIMENSIONS | ||
Dimensions L x W x H | 800 x 800 x 2000 mm | 800 x 800 x 2000 mm |
Weight | 250 kg | 300 kg |
Options | RS-485 communications (RS-232 standard), Isolation contactors, MG Weld monitors, Cable throughput top cabinet |
Send your sample to one of our technology centers in Europe for an evaluation. We will then determine which solution meets your needs best. AMADA WELD TECH offers feasibility testing and application consulting.